11 - 2 11 - 2
MELSOFT
11. POSITIONING DEBUGGING
11.1 Monitor
Monitor the positioning data and start block data execution states on an axis basis or
perform extended monitor of the error histories, signal states, current values, speeds,
etc. of all axes.
11.1.1 Monitoring the positioning data/start block data
PURPOS
E
From the screen of the positioning data/start block data of any axis, monitor the
positioning data No.s or block No.s and point No.s being executed, and further
monitor the operating status indicators such as the feed addresses, feed speeds,
error/warning codes and M codes.
BASIC OPERATIO
N
1. Choose the positioning or start block data to be monitored.
Double-click any of the items.
Doble-click.
2. Click the [Online] → [Monitor] → [Monitor start] menu (
).
3. Choose "Data Up-loading" (read from AD75) or "Data Down-loading" (write to
AD75) in the monitor mode start confirmation dialog box.
4. Click the "Extended" button and set the required data and range in the Write or
Read dialog box.
5. Click the "OK" button in the monitor mode start confirmation dialog box.
6. To exit, click the [Online] → [Monitor] → [Monitor start] menu (
).
11