Section 11 Multi-Function Timer Pulse Unit 2
R01UH0134EJ0400 Rev. 4.00 Page 581 of 2108
Sep 24, 2014
SH7262 Group, SH7264 Group
A/D converter start request (TRG4AN)
Note: * When the interrupt skipping count is set to two.
TGIA_3 interrupt
skipping counter
TCIV_4 interrupt
skipping counter
TGIA_3 A/D request-enabled
period
TCIV_4 A/D request-enabled
period
When linked with TGIA_3 and TCIV_4
interrupt skipping
When linked with TGIA_3
interrupt skipping
When linked with TCIV_4
interrupt skipping
TADCORA_4
TCNT_4
00 01 00 0102
00 01 00 0102
UT4AE = 1
DT4AE = 0
Figure 11.76 Example of A/D Converter Start Request Signal (TRG4AN) Operation
Linked with Interrupt Skipping