Mitsubishi Electronics A1SD75M1/M2/M3 Model Vehicle User Manual


 
11 - 8 11 - 8
MELSOFT
11. POSITIONING DEBUGGING
11.1.4 Signal monitor
PURPOS
E
Monitor the I/O signals (X/Y devices), external I/O signals and status signals of the
AD75.
For the signals, refer to the AD75 User's Manual.
BASIC OPERATIO
N
1. Perform the basic operation in Section 11.1.2 to display the operation monitor
main screen.
2. Click the "Signal" button on the operation monitor main screen.
3. Click the <<X/Y device>>/<<External I/O>>/<<Status info.>> tab.
4. To exit, click the "Close" button.
DISPLAY/SETTING SCREEN
[X/Y device monitor]
(Screen example: Screen displayed when AD75M# is selected in Change AD75 model)
DISPLAY/SETTING DATA
Item Description
X/Y device
Displays ON of the I/O signals of the AD75.
If AD75M# is selected in Change AD75 model, Not for use is displayed at Y15.