40
timer as needed, and be sure to disable the alarm (Menu 5 set to zero [
0
]) to prevent tripping
the No-Convey alarm
Er.1
.
Menu 2 Number of Blowback Pulses
0 to 16 Pulses, Default = 4 Pulses
The Number of Blowback Pulses menu lets you:
control the number of blowback pulses discharged from the
compressed air solenoid during the hopper dump sequence
increase the number of pulses if the material conveyed exhibits
bridging problems or otherwise dumps slowly
decrease the number of pulses to optimize the cycle time and
increase throughput when conveying free-flowing material
Menu 3 Percentage of Material B
0 to 100 Percent, Default = 0 Percent
PP Models Only
The Percentage of Material B menu lets you increase or decrease the percentage of
Material B in the proportioning cycle.
Menu 4 SPV Total Cycle Time
0 to 60 Seconds, Default = 30 Seconds
PP Models Only
The SPV Total Cycle Time menu lets you:
control the duration of a complete proportioning cycle—this time is
not the same as the vacuum time; the vacuum and proportioning
timers operate concurrently as shown in Figure 10.
decrease the SPV total cycle time to increase the layering of the
two materials in the hopper loader as it fills
increase the SPV total cycle time to reduce the layering of the two
materials in the hopper loader as it fills
Example: If the percent of Material B (Menu
3
) is set at 20% and the SPV
total cycle time (Menu
4
) is set at 40 seconds, Material B
conveys for twenty percent (20%) of
40 seconds, or eight (8) seconds. Material A conveys for the
remaining 32 seconds.