provides volume-fill control. When the hopper loader is full, the LED on the proximity switch
should light and trigger the dump sequence.
If the switch does not reliably sense the material you are conveying, adjust switch sensitivity.
Turn the potentiometer (or pot) clockwise to increase sensitivity, counterclockwise to decrease
sensitivity.