Sterling SSL Card Game User Manual


 
39
Press the
S
START/STOP
START/STOP/SELECT/SET key.
The new setting is stored in the battery-backed RAM memory.
If you decide that you don’t want to modify the current setting of a parameter:
Press the
SCROLL
SCROLL key to abort the change.
The change is aborted and the
AEC
screen displays again.
To return all parameters to factory default values:
Turn off the Series One Plus using the green power switch.
Press and hold both the
CLEAR
UP key and DOWN key together
simultaneously as you turn on the Series One Plus green power
switch.
All menu parameters are restored to factory default values.
5-11 Series One Plus Operating Parameter Menus
Menu 1 Maximum Vacuum Cycle Time
0 to 360 Seconds, Default = 60 Seconds
For volume-fill operation, the Maximum Vacuum Cycle Time menu lets you set the
maximum vacuum motor time during a conveying sequence. If the level sensor in the hopper
loader does not detect a full loader when the time you set elapses, the vacuum motor stops and
the loader dumps. Increase this time setting if it takes longer than sixty (60) seconds to fill the
loader.
Note: To optimize operation, set the timer in this menu to approximately
ten (10) seconds longer than the time it takes to fill the loader
under your current conveying conditions.
To determine how long it takes to fill the loader, watch the timer
count up during operation. When the display changes to - - - -
(dashes), the loader is full. Add ten (10) seconds to the value
displayed right before the display changes to
- - - - (dashes).
For time-fill operation, more frequent loading cycles, or less material conveyed per cycle, you
can set this parameter so the vacuum motor stops and the loader dumps before it is full. Set the