Sterling SSL Card Game User Manual


 
31
BLOWBACK
BLOWBACK Indicator
The BLOWBACK indicator lights when the air solenoid is open.
MATERIAL "B"
MATERIAL “B” Indicator
The MATERIAL “B” indicator lights when the Material B port is open.
5-4 Starting Up the Hopper Loader for the First Time Using the
Series One Plus Controller
Non-Proportioning Models
1. Insert the pickup wand into the material supply.
2. Turn on the compressed air to the hopper loader.
3. Apply power to the controller.
Note: Press and hold the
CLEAR
UP key and DOWN key together
simultaneously while applying power to restore all factory
defaults.
As the controller powers up, the screen displays in succession:
PLUS
for three seconds
the software version number
n.nn
the standby mode display.
4. Press the
S
START/STOP
START/STOP/SELECT/SET key to start the
hopper loader.
The vacuum motor conveys material until the proximity sensor
indicates the hopper loader is full or the factory-pre-set default
maximum vacuum time of sixty seconds passes, whichever comes
first. The VACUUM and MATERIAL “A” LEDs light and the
LED display shows the elapsed conveying time.