3
Important Safety Instructions
IMPORTANT SAFETY INSTRUCTIONS Specic to Secondary
Means of Protection Against Entrapment
AsspeciedbyUnderwritersLaboratoriesInc.UL325(30A.1.1),automaticgateoperatorsshallhaveprovisions
for, or be supplied with, at least one independent primary and one independent secondary means to protect
against entrapment. GTO gate operators utilize Type A, an inherent entrapment sensing system, as the primary
type of entrapment protection. The GP-SW050 operators have provisions for the connection of Type B1, B2, or
D protection to be used as the secondary type of entrapment protection.
1.Forgateoperatorsutilizinganon-contactsensor(TypeB1)inaccordancewithUL325(51.8.4[h]):
A. Refertothesensormanufacturer’s instructions on the placement of non-contact sensors for each type of
application.
B. Careshallbeexercisedtoreducetheriskofnuisancetripping,suchaswhenavehicletripsthesensor
whilethegateisstillmoving.
C. Oneormorenon-contactsensorsshallbelocatedwheretheriskofentrapmentorobstructionexists,
such as the perimeter reachable by a moving gate or barrier.
2.Forgateoperatorsutilizingacontactsensor(TypeB2)inaccordancewithUL325(51.8.4[i]):
A. Oneormorecontactsensorsshallbelocatedattheleadingedge,trailingedge,andpostmountedboth
insideandoutsideofavehicularswinggatesystem.
B. Ahardwiredcontactsensorshallbelocatedanditswiringarrangedsothatthecommunicationbetween
the sensor and the gate operator is not subjected to mechanical damage.
C. Awirelesscontactsensorsuchasonethattransmitsradiofrequency(RF)signalstothegateoperator
forentrapmentprotectionfunctionsshallbelocatedwherethetransmissionofthesignalsarenot
obstructedorimpededbybuildingstructures,naturallandscapingorsimilarobstruction.Awireless
contact sensor shall function under the intended end-use conditions.
3. For gate operators utilizing an actuating device requiring continuous pressure to maintain opening or
closingmotionofthegate(TypeD)inaccordancewithUL325(51.8.4[e]):
A. Thegateoperatorcontrolsmustbeplacedsothattheuserhasfullviewofthegateareawhenthegate
is moving.
B. Warning signs (see page 6) shall be placed adjacent to the controls.
C. Nootheractivationdeviceshallbeconnected.
ENTRAPMENT ALARM (UL 325; 30A.1.1A)
TheGP-SW050operatorsaredesignedtostopandreversefor2secondswhenthegatecomesincontact
withanobstructionorwhenanobjectactivatesthenon-contactsensors.Additionally,theseoperators
areequippedwithanaudio entrapment alarmwhichwillfunctioniftheunitobstructstwicewhile
openingorclosing.Thisalarmwillsoundforaperiodof5minutesoruntiltheoperatorreceivesan
intended signal (e.g., transmitter signal) and the gate returns to a fully open or fully closed position.