GTO GP-SW050 Safety Gate User Manual


 
19
1 2 3 4
ON
LOCK
ALARM
CYCLE
SAFETY
SHADOW
OPEN
EDGE
STATUS
STALL FORCE ADJUST
DUAL
LINK
GTO LOOP DETECTORS
LIMIT SENSORS
DIAG.
PORT
BLDC SPEED CONTROL
EXIT SHADOW SAFETY
AT OPEN
LIMIT
PRISON
MODE
RUNNING
OPTIONS
<<<
>>>
CLOSED
LED11
LED10
LED09
+ ACC. PWR.
12VDC
- 300ma
AUTO CLOSE
TIMER
MODE 1
MODE 2
OPEN DIR.
SLV OPN
DUAL MODE
LOW BATT
ON
ON
>>>
SIMUL
SLAVE
SECURE
OFF
OFF
<<<
DELAY
MASTER
SAFE
CYCLE
SAFETY
OPEN EDGE
RUN 2
OPEN
CLOSE
STOP
COM
COM
COM
SHADOW
LOOP
RELAY OUTPUTS
LOCK N.C.
LOCK COM
LOCK N.O.
RUN 1
RUN 2
CLOSED 1
CLOSED 2
1 2 3 4
ON
STALL FORCE ADJUST
OPTIONS
<<<
>>>
MODE 1
MODE 2
OPEN DIR.
SLV OPN
DUAL MODE
LOW BATT
ON
ON
>>>
SIMUL
SLAVE
SECURE
OFF
OFF
<<<
DELAY
MASTER
SAFE
1 2 3 4
ON
ON
OFF
DIP Switch Settings
MODE 1 & MODE 2:
• Reservedforfuturefeatures
DIP #1: OPEN DIRECTION
• OFF:forgatethatopenstotheleft,closestotheright.
• ON:forgatethatopenstotheright,closestotheleft.
DIP #2: SLAVE OPEN SEQUENCE (dual gate installation only)
• NOTE:ThisDIPswitchisapplicableifandonlyifallthe
followingconditionsarevalid:
• DIPswitch#3isOFF(Mastermode)
• DualLinkcableisconnected.
• Slavemodeisdetectedfromthesecondboard(DIPswitch#3
ofthesecondboardisON)
• Iftheaboveconditionsarenotmet,theboardwilldefaultto
singlegateoperation.IfDIP#3isOFF(Master)
• OFF:Slavegatewillopenafterthemastergate.
• ON:Slavegatewillopensimultaneouslywiththemastergate.
DIP #3: MASTER/SLAVE (applicable to dual gate installation only)
• NOTE:ThisDIPswitchisapplicableifandonlyifallthe
followingconditionsarevalid:
• DualLinkcableisconnected.
• Thesecondoperatorisdetectedbythemaster.
• Iftheaboveconditionsarenotmet,theboardwilldefaultto
singlemodeoperation.IfDIP#3isOFF(Master)
• OFF:Mastermodeoperationindualgateinstallationifslave
setting is detected from the other board.
• ON:Slavemodeoperationindualgateinstallationifmaster
setting is detected from the other board. Control board is non-
functional if master operator is not detected.
DIP #4: FAIL SAFE/FAIL SECURE OPERATION
• OFF:Failsafemode
WhenlowbatteryandnoACpowerconditionsaredetected
thegatewillautomaticallyruntotheopenedposition.The
gatewillremainattheopenpositionuntilACpowerisrestored
and the battery reaches an acceptable charge level.
• ON:Failsecuremode
WhenlowbatteryisdetectedandnoACpowerispresent,the
gatewillautomaticallyruntotheclosedposition.Gatewill
auto close only if auto close feature is enabled and gate is at
openlimit.ThegatewillremainattheclosedpositionuntilAC
powerisrestoredandthebatteryreachesan
acceptable charge level.
Theseswitchesarefordualgate
applications only. See page 26 for
dual gate settings.