Setting the Limits
OPEN LIMIT SETTING:
1. Turnonoperatorpower.
2. Press and release the OPEN button on the board and be prepared to press the STOP button
whenthegatereachedthedesiredopenposition/limit.
3. The JOG buttons can be used to bring the gate to the precise open position. The JOG buttons
willslowlyrunthegatewhenpressedandstopthegatewhenreleased.
4. Once at the desired open position, press and hold the SET LIMIT button for 3 seconds or until
the alarm sounds and STATUS LEDison.Atthistime,releasethe SET LIMIT button.
5. Bepreparedtostopthegatewhenitreachestheclosedposition.
CLOSED LIMIT SETTING:
1. Ifnotalreadyclosed,pressandreleasetheclosebutton.
2. Press and release the CLOSE button on the board and be prepared to press the STOP button
whenthegatereachedthedesiredclosedposition/limit.
3. The JOG buttons can be used to bring the gate to the precise closed position. The JOG buttons
willslowlyrunthegatewhenpressedandstopthegatewhenreleased.
4. Once at the desired closed position, press and hold the SET LIMIT button for 3 seconds or until
the alarm sounds and STATUS LEDison.Atthistime,releasethe SET LIMIT button.
5. Openthegatetoallowittostoponitsown.
6. Openandclosethegatetoverifyproperoperations.Iflimitsarenotset
properly, redo limit setting steps above.
NOTE: If limits are too short, use jog button to move arm short distances to stop gate at
the precise open or closed position.
CAUTION: Be extremely careful not to stand in the path of the gate arm while setting limits.