30
TroubleShooting Guide
WARNING: ALWAYS TURN OPERATOR OFF AND DISCONNECT
BATTERIES BEFORE ADJUSTING OR SERVICING IT.
SYMPTOM DIAGNOSIS CHECK
One beep every 5 seconds
whenthegateisinmotion.
ThereisnoACpowerpresent.
Thebatteryvoltageislow.
• GFI
• CircuitBreaker
• ConnectionsintheFieldWiring
Connection Compartment
• BatteryConnections
• BatteryVoltage
• LoadTestBattery
One beep every 10 seconds
whenthegateisidle.
Thebatteryiscriticallylow.
If#4dipswitchisintheFAILSAFE
positionandthegateisattheOPEN
Limit,theoperatorwillbedisableduntil
ACpowerisrestoredandthebattery
voltage has reached 26 vdc.
If#4dipswitchisintheFAILSECURE
positionandthegateattheCLOSED
Limit,theoperatorwillbedisableduntil
ACpowerisrestoredandthebattery
voltage has reached 26 vdc.
• GFI
• CircuitBreaker
• ConnectionsintheFieldWiring
Connection Compartment
• BatteryConnections
• BatteryVoltage
• LoadTestBattery
1beepwith2seconds
pause
The revolution counter circuit board is
not being detected.
• CheckConnectionsforLimit
Sensors on Logic Board
2beepswith2seconds
pause
The logic board does not detect the
motor drive board connections.
• CheckBLDCSpeedControl
connections on Logic Board and
MotorDriveBoard
3beepswith2seconds
pause
The gate has traveled outside the
maximumallowablelimitofthe
operator.
• CheckLimitSensorConnections
on Logic Board
4beepswith2seconds
pause
Themotorhasmovedinthewrong
direction.
• CheckBLDCSpeedControl
connections on Logic Board and
MotorDriveBoard
5beepswith2seconds
pause
Nomovementwasdetectedfromthe
motortwice.
• CheckpathofGatefor
obstructions.
• Checktoensuremotorisnot
jammed.
GP-SW050 Audible Feedback