Sterling Plumbing scc2 Musical Table User Manual


 
Hopper Loaders with/without Sight Glasses 36
If these conditions are not all met, error messages appear on the screen instead
of a Transfer to Standby Pump button. If you get an error message, first
check to make sure that you have entered the correct numbers and reenter if
necessary. If another error occurs, see the Standby Pump Errors section below.
10. Touch Transfer To Standby Pump. “Transfer in Progress” appears briefly on the
screen, followed by “Transfer Complete,” in place of the Transfer To Standby
Pump button. The controller switches the setting for Source Pump to the new
pump and switches the setting for Standby Pump to 0 (unassigned).
11. Touch Return, and then Pumps to return to the “Pump Status” screen.
12. Put the standby pump online by briefly touching its icon. The icon changes color to
show the new status, and the system begins using the pump. In addition, all “Station
Operator” and “Station Setup” screens show the new pump assignment.
When the failed pump is operational again, you can repeat this process, this time using the
standby pump’s number as the setting for Source Pump the repaired pump’s number as the
setting for Standby Pump.
Standby Pump Errors
If the error message tells you to disable the source pump and/or the standby pump, touch
Return at this screen, then Pumps at the “Pump Setup” screen. Take the pumps offline and
then return to the “Transfer to Standby Pump” screen.
If the error message tells you that the standby pump has stations assigned, you must either use
a different standby pump or you must remove the pump assignment for all stations assigned
to the standby pump. To remove the assignments, complete the following steps:
1. Touch Return at the “Standby Pump” screen, and then touch Menu.
2. From the “Menu” screen, touch Stations.
3. Touch and hold a station icon to get to the “Station Operator” screen.
4. Then touch Setup to go to the “Station Setup” screen.
5. Use Back. and Next to review all pump assignments.
6. Where necessary, choose Assigned to Pump #n to set station assignments to 0
(unassigned). Then return to the “Transfer to Standby Pump” screen.
4-4 Alarms
Reviewing Alarms
To review your system’s alarms, touch Alarms on “Menu” screen. The “Alarm Log” screen
appears, with the newest alarm listed first.
Note: Alarm log is not resettable! Log holds the 100 most recent alarms.