Sterling Plumbing scc2 Musical Table User Manual


 
2–Pump 20-Station Controllers Operation 33 of 51
Activating and Stopping Priority Convey for a Station
Note: Before activating priority convey, make sure that all other stations using the same
pump have adequate material in reserve to continue operation. No material will be
conveyed to these stations during priority convey.
If you want the controller to fill a specific station with material immediately, you can activate
“priority convey” for that station. When you do so, the controller temporarily dedicates the
station’s pump to it, ignoring demands from other stations assigned to that pump. Once the
chosen station is full, normal operation resumes.
You can also use this feature to give one station a “head start” by conveying a few loads to it
and then stopping the priority convey.
No more than one station for a given pump can be in “priority convey” at once. To activate
priority convey, complete the following steps:
1. Go to the “Station Operator” by touching and holding a station icon, or go to the
“Station Setup” screen.
2. Touch Priority Convey Activate. The button changes to Priority Convey Active
and blinks until the station’s demand has been satisfied (or you stop the priority
convey). The controller begins filling the chosen station only (after finishing any
conveying already in progress).
3. To stop a priority convey before the station is completely full, touch the blinking
Priority Convey Active button. The button changes to Priority Convey Activate
and stops blinking. The controller finishes the current convey, if any, and resumes
normal operation.
4-3 Adjusting Advanced Settings
This section describes the procedures carried out during operation that are normally reserved
for setup personnel. These procedures require use of the setup password (if your facility has
defined one). The procedure for logging on and off with the setup password is the same as for
logging on with the operator password; see p.32 for step-by-step instructions for logging on
and off.
Reviewing and Resetting a Pump Hour Meter
The controller keeps two meters for the length of time a pump has run. One, like a car’s
odometer, keeps a running total and cannot be reset. The other, like a car’s trip odometer,
counts the running time since the last reset.
To review and reset the hour meter, complete the following steps:
1. At any screen, touch the Menu, and then touch Pumps. The “Pump Status” screen
opens.
2. Touch and hold the icon for the pump. The “Pump Setup” screen opens.