Lexicon MC-12 Baby Monitor User Manual


 
MC-12 Setup
3-47
PERFORMING AUTOMATIC CALIBRATION
Follow the procedures in the appropriate table column for the desired type of automatic calibration.
STEP DISTANCES DISTANCES & LEVELS LEVELS
1
2
AUTO SPEAKER SETUPSPEAKER SETUP
SET CROSSOVERS
CHECK MICROPHONES
AUTOMATIC
MANUAL
CUSTOM SETUP
40 Hz
60 Hz
60 Hz
60 Hz
40 Hz
OFF
N/A
APART
AUTO SPEAKER SETUP
DISTANCES & LEVELS
SET CROSSOVERS
BEFORE CALIBRATING
MAIN MENU
MODE ADJUST
AUDIO CONTROLS
SETUP
DISTANCES
OUTPUT LEVELS
PLACE MICROPHONES
IN PRIMARY LISTENING
POSITIONS
CUSTOM SETUP
40 Hz
60 Hz
60 Hz
60 Hz
40 Hz
OFF
N/A
APART
AUTO SPEAKER SETUP
!CAUTION!
HIGH AUDIO LEVELS
TEST WILL BEGIN IN
10
YOU WILL HAVE 10 SEC
TO LEAVE THE ROOM OR
SIT QUIETLY
PRESS TO BEGIN
COUNTDOWN
PRESS TO SKIP
COUNTDOWN
SETUP
INPUTS
SPEAKERS
REAR PANEL CONFIG
DISPLAYS
VOLUME CONTROLS
TRIGGERS
LOCK OPTIONS
LIVE! CALIBRATION
Select the SPEAKER SETUP menu AUTOMATIC option as shown in the menu illustration above.
If a microphone check is successful, the AUTO SPEAKER SETUP menu becomes available on the on-screen display. Press
the or arrow button to highlight the automatic calibration option you want. Then, press the arrow button to select
this option. Refer to the table on page 3-35 for more information about automatic calibration options.
If a microphone check is unsuccessful, one of the error messages shown at the right appears on the on-screen display, indicat-
ing that a successful microphone check is required before automatic calibration is available, and also the reason the previous
check failed. If this occurs, go back to “Connecting the Microphones” on page 3-36 and work your way forward to this page.
M I C C H E C K R E QU I R E D
FOR AUTO CALIBRATION
NO MICROPHONE
DETECTED
The following AUTO SPEAKER SETUP messages display on-screen before automatic calibration begins:
The !CAUTION! HIGH AUDIO LEVELS message indicates that the MC-12 generates loud calibration noise signals during automatic calibration. If the
signals become too loud, press the
arrow button to cancel automatic calibration. Press the arrow button to open the next AUTO SPEAKER
SETUP menu.
The countdown display notifies you that automatic calibration will begin in 10 seconds. The primary reason for the 10 second delay is to give you time
to leave the listening space before automatic calibration begins. If you choose to remain in the room, your movements could affect the calibration
results. If you leave the room, you can return in about 10 minutes (the calibration procedure should be completed). Press the
arrow button to
skip the countdown and begin automatic calibration. The MC-12 automatically activates automatic calibration when the countdown ends.