A SERVICE OF

logo

Commander GP User Guide
Issue code: gpxu2
A-2 Programming Instructions
A.3 Status mode
The lower display shows rdY to indicate that the
Drive is ready to drive a motor, as follows:
The upper display indicates the output frequency of
the Drive or the motor speed. This is the value of
parameter 0.10. (The value of a different parameter
could be shown if the Drive has been used
previously.)
A.4 Displaying the parameter
number in Status mode
When the display is in Status mode, the upper
display shows the value of parameter 0.10 (or of the
last parameter to be selected). The number of this
parameter can be shown on the lower display
instead of the Drive status.
1. To show the parameter number, press:
or
2. To show the status, press: . The status is
shown immediately.
A.5 Entering Parameter mode
and returning to
Status mode
1. Momentarily press . The display enters
Parameter mode.
The lower display shows parameter number
0.10. (A different parameter number could be
shown if the Drive has been used previously.)
The display appears as follows:
8 seconds
2. Do not press any keys. After eight seconds, the
display returns to Status mode. This shows
that the display always returns from Parameter
mode to Status mode when no keys are pressed
within eight seconds.
You may repeat these two steps as many times
as required to obtain an understanding of the
operation.