59
Digital Dosing unit parameter setup 7-14
Bison - Black motor Bauer - Blue motor Comments
Parameter
RPM 2 6 12 38 6.4 11.5 35.5
7
65000 25200 14103 4387 11739 6600 2135 These values refer to the pulses of the encoder
8
0.5 0.7 Nominal motor current
9
Ext Inj Ext Inj
1040 16 1040 16 (see separate calculation sheet for parameter #9)
10
0 1 Factory set, do not change
11
Ext Inj Ext Inj
50 50 50 50 Ext = minimum input frequency w/follower only
Inj = Minimum # of machine cycles per dosing
12
Ext Inj Ext Inj
10 5.56 10 5.56
Ext = Span factor (sf) calculated using: sf=1000/rpm@10vdc
sf = 1000/rpm @20ma
13
Ext Inj Ext Inj
0 0 0 0
Communication address used with Euromap 17 (use 1instead of 0)
14
Ext Inj Ext Inj
0 0 0 0 For use with Mico mix hopper (use 1 instead of 0)