17. Install the dosing container along with the dosing hopper on the dosing housing (pay
attention to the guide pins).
18. Mount the profile clamp.
19. Mount the screw at the profile clamp and tighten.
5.7 Exchangeable Stations
Dosing discs of the same type may be exchanged for each other without any problems. If dosing
discs with a different compartment number are installed, this has to be entered in the control
system.
1. Enter the (preliminary) calibration value of the freshly installed dosing disc (*=bulk
density 550g/l, ** = bulk density 700g/l).
2. Execute “calibration” to determine the final calibration value.
5.8 Replacing Fuses
1. Stop the continuous operation.
2. Wait until the dosing unit has come to a standstill.
3. Switch off the device by means of the on/off switch.
4. Cut off the voltage supply.
5. Wait at least one minute before starting to work at the switching cabinet.