Sterling BF3-600 Doll User Manual


 
Digital Dosing Units
39
Installing Different Types of Dosing Discs
Dosing discs of the same type may be exchanged for each other without any problems. If dosing
discs with a different compartment number are installed, this has to be entered in the control
system!
1. Enter the (preliminary) calibration value of the freshly installed dosing disc (* = bulk
density 550g/l, ** = bulk density 700g/l).
2. Execute “calibration” to determine the final calibration value
.
5.5 Removing/Replacing the Scraper in the DT Dosing Station
1. Empty the dosing station.
2. Open the profile clamp (C) of the
dosing container.
3. Remove the profile clamp (C)
4. Remove the dosing container (B)
along with the dosing hopper (A).
5. Loosen the 3 plastic screws on the
stripper (DT-t: metal screws).
6. Remove the scraper and holding
plate.
7. Install the new scraper along with the holding plate.
8. Tighten down the 3 plastic screws. Make sure that the stripper is fitted parallel to the
dosing plate (Use only plastic screws (DT-t: metal screws).