3. FUNCTION LIST
3. FUNCTION LIST
3.1 Function List
(1) Function list
GX Configurator-AP functions are listed below mode-by-mode.
Mode Main Screen Function Description
Parameter Parameter setting
Set the basic parameters1, basic parameters2, extended
parameters1, extended parameters2, OPR basic parameters and
OPR extended parameters on an axis basis.
Servo parameter
(AD75M only)
Servo parameter
setting
Set the servo basic parameters, servo adjustment parameters and
servo extension parameters on an axis basis.
Positioning data
setting
Set the positioning data, such as pattern, control method,
accel/decel time and address, on an axis basis.
Positioning data
monitor
Monitor the positioning data during execution on an axis basis.
Positioning data test
Perform test operation of positioning control on an axis or
positioning data basis.
Teaching
Set the feed address of the moved axis to the address of
positioning data by JOG operation or the like.
M code comment
setting
Set comments to the M codes assigned to the positioning data on
an axis basis.
Positioning data
axis #1
Positioning data
axis #2
Positioning data
axis #3
Offline simulation
Assume axis operation from the set positioning data on an axis
basis.
Start block data
setting
Set the starting mode, etc. of the positioning data specified for
points on an axis basis.
Start block data
monitor
Monitor the point at which positioning control is being executed on
an axis basis.
Start block data test
Perform test operation of positioning control from the point of the
specified block on an axis basis.
Condition data
setting
Set the data which is used as the starting condition of the start
block data on an axis basis.
Edit
Start block axis
#1
Start block axis
#2
Start block axis
#3
Indirect data setting
Set the positioning data numbers set to the indirect designating
buffer memory of the AD75 on an axis basis.
Operation monitor
(main screen)
Monitor the operating states, such as addresses, axis speeds, axis
statuses and executed positioning data numbers, of all axes.
History monitor
Monitor the error, warning, start or error-time start history of all
axes.
Signal monitor
Monitor the X/Y devices, external signals or status signals of all
axes.
Operation monitor
(dialog)
Monitor the control states, AD75 parameter settings or others of all
axes.
Servo monitor Monitor the servo amplifier and servomotor states of all axes.
Monitor
Operation
monitor (test)
Operation test
Test the positioning data number-specified start, current value
change, speed change, original position return, JOG operation and
manual pulse generator operation of all axes.