Mitsubishi Electronics AD75P1-S3/P2- S3/P3-S3 Model Vehicle User Manual


 
11 - 38 11 - 38
MELSOFT
11. POSITIONING DEBUGGING
11.2.6 JOG operation test
PURPOS
E
JOG operation allows the following tests to be made during debugging of
positioning.
Forward/reverse direction checking
Checking of the ON/OFF of the external signals such as upper/lower limit, zero
phase and DOG signals
Speed and accel/decel operation tests
Measurement of backlash compensation by forward or reverse operation
BASIC OPERATIO
N
1. Perform the basic operation in Section 11.1.2 to start operation monitor.
2. Click the [Online] [Test] [Test start] menu (
).
3. Click the "OK" button in the test mode start confirmation dialog box.
4. Click the "Ope. Test" button on the operation monitor main screen.
5. Click the <<JOG>> tab in the Test data set dialog box.
6. Perform JOG operation according to the purpose.
7. To end the JOG operation test, click the [Online] [Test] [Test start] menu (
).
8. Clicking the "OK" button in the test mode end confirmation dialog box returns to
the operation monitor status.
DISPLAY/SETTING SCREEN