Fuser failure detection
The DC controller determines a fuser unit failure, deactivates the FUSER HEATER CONTROL signal,
releases the relay to interrupt power supply to the fuser heater and notifies the formatter of a failure
state when it encounters the following conditions:
Start-up failure
If the main thermistor does not detect a specified temperature during the start-up process of
the heater in the wait period.
If the main thermistor does not detect a specified temperature during the heater temperature
control in the initial rotation period.
Abnormal low temperature
If the main thermistor detects an abnormal low temperature of the fuser unit during the printing
operation.
If the sub thermistor detects an abnormal low temperature of the fuser unit during the printing
operation.
Abnormal high temperature
If the main thermistor detects an abnormal high temperature of the fuser unit.
If the sub thermistor detects an abnormal high temperature of the fuser unit.
Frequency detection circuit failure
If a specified frequency of the ZERO CROSSING signal is not detected within a specified
period after the product is turned on.
ENWW Engine-control system 17