Mitsubishi Electronics AD75P1/P2/P3 Model Vehicle User Manual


 
7 - 5 7 - 5
MELSOFT
7. SYSTEM CHECKING FROM PERIPHERAL DEVICE
HELPFUL CORRECTIVE ACTIONS
Take the following corrective actions when AD75P checking connect cannot be
completed properly.
Status Corrective Action
AD75P checking connect
cannot start
Check the connection of cables with the AD75P.
Using the optional function (refer to Section 12.5), check whether COM setting is correct.
Check that the servo amplifier is powered.
Drive unit ready is OFF
Check the connection of the external I/O signal connector.
Check the connection of the external I/O signal connector.
Upper/lower limit is OFF
Check for contact of the upper/lower limit switch.
JOG operation cannot be
performed.
Check that JOG speed setting is not "0".
Error/warning occurred Check the error/warning code using [Help], and check and remove the cause.