FUNCTION TESTS
Test the Tilt Sensor
9 Pull out the platform red
Emergency Stop button to
the on position. Turn the
key switch to platform
control.
10 Open the engine side
turntable cover and locate
the tilt sensor to the right of
the hydraulic pump.
11 Press down one side of the tilt sensor.
Result: The alarm, located in the platform,
should sound.
Test Auxiliary Controls
12 Turn the key switch to ground control and shut
the engine off.
13 Pull out the red Emergency Stop button to the
on position.
14 Simultaneously hold the auxiliary power switch
on and activate each boom function toggle
switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.
1 Select a test area that is firm, level and free of
obstruction.
At the Ground Controls
2 Turn the key switch to ground control.
3 Pull out the red Emergency Stop button to
the on position.
Result: Beacon (if equipped) should flash.
4 Start the engine. See Operating Instruction
section.
Test Emergency Stop
5 Push in the red Emergency Stop button to the
off position.
Result: The engine will shut off after 2 to 3
seconds.
6 Pull out the red Emergency Stop button to
the on position and restart the engine.
Test the Machine Functions
7 Do not hold the function enable switch to either
side. Attempt to activate each boom and
platform function toggle switch.
Result: All boom and platform functions should
not operate.
8 Hold the function enable switch to either side
and activate each boom and platform function
toggle switch.
Result: All boom and platform functions should
operate through a full cycle. The descent alarm
(if equipped) should sound while the boom is
lowering.
Machines equipped with Platform Level Control
Disable Function: The platform level toggle switch
will not operate when the primary boom is raised
past the drive speed limit switch.