Genie Z-45/25 Riding Toy User Manual


 
Part No. 52421 Genie Z-45/25 & Genie Z-45/25J 13
Operator's ManualFirst Edition · Seventh Printing
Deutz Engine F3L 1011F
Oil viscosity requirements
below 60°F / 15.5°C (synthetic) 5W-30
-10°F to 90°F / -23°C to 32°C 10W-40
above -4°F / -34°C 15W-40
Engine oil should have properties of API classification
CC/SE, CD/SE, SF/CC or SF/CD grades.
Units ship with 10-40 CC/SG.
Perkins Engine 104-22
Oil viscosity requirements
below 60°F / 15.5°C 5W-20
-10° to 90°F / -23° to 32°C 10W-30
above -10°F / -23°C 15W-40
above 25°F / -4°C 20W-50
Engine oil should have properties of API classification
CC/SE, CD/SE, SF/CC or SF/CD grades.
Units ship with 10-40 CC/SG.
Check the Hydraulic Oil Level
Maintaining the hydraulic oil at the proper level is
essential to machine operation. Improper hydraulic
oil levels can damage hydraulic components. Daily
checks allow the inspector to identify changes in oil
level that might indicate the presence of hydraulic
system problems.
1 Be sure that the boom is in the stowed position,
then visually inspect the sight gauge located on
the side of the hydraulic oil tank.
Result: The hydraulic oil level should be within
the top 2 inches / 5 cm of the sight gauge.
2 Add oil as needed.
Hydraulic oil specifications
Hydraulic oil type Dexron equivalent
MAINTENANCE