Pelco CM9760-CXTA Model Vehicle User Manual


 
10 Pelco Manual C539M-A (12/01)
2.1.4.2 Protocol Type
This bit is set to correspond to the protocol input of the associated controller (see Figure 7).
Figure 7. Protocol Type
2.1.4.3 Unused DIP Switch
DIP switch position 1-4 is not used but is reserved for future use.
Figure 8. Unused Configuration Bit
2.1.4.4 BAUD Rates
The baud rate chosen must correspond to the the communicaiton baud rate of the control-
ler to which the CXTA is attached.
Note, as Figure 9 states, that these settings apply to attached P protocol controllers. The trans-
lator reverts to a fixed baud rate of 2400 if a D type controller is interfaced. The baud rate
settings of DIP 1-5 and 1-6 are ignored.
Figure 9. Baud Rate Settings
NOTE:
When protocol is
set for D (DIP 1-3 ON), then
the existing baud rate
settings (DIP 1-5 and 1-6)
for the configuration switch
are ignored. D protocol
operates independent of
baud rate setting and
automatically reverts to a
fixed baud rate of 2400
(8-bit, no parity, 1 stop).