11 - 41 11 - 41
MELSOFT
11. POSITIONING DEBUGGING
11.2.7 MPG operation test
PURPOS
E
MPG operation allows the following tests to be made during debugging of
positioning.
Checking of the ON/OFF of the external signals such as upper/lower limit, zero
phase and DOG signals
Measurement of backlash compensation by forward or reverse operation
Measurement of accurate addresses and travel distances
BASIC OPERATIO
N
1. Perform the basic operation in Section 11.1.2 to start operation monitor.
2. Click the [Online] [Test] [Test start] menu (
).
3. Click the "OK" button in the test mode start confirmation dialog box.
4. Click the "Ope. Test" button on the operation monitor main screen.
5. Click the <<MPG>> tab in the Test data set dialog box.
6. Enable MPG operation.
7. Perform MPG operation.
8. To end the MPG operation test, click the [Online] [Test] [Test start] menu (
).
9. Clicking the "OK" button in the test mode end confirmation dialog box returns to
the operation monitor status.