4. Sanitizing Procedure - Initial
1) Close the water supply line shut-off valve.
2) In the storage bin, remove the thumbscrews attaching spout (B), then remove spout (B)
and spout packing (B).
3) Remove the thumbscrews attaching spout (A) to the evaporator assembly and
lift off spout (A) and spout packing (A), and the cylinder packing.
4) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are lled and the solution starts to overow into the drain pan.
5) Remove the thumbscrews attaching the bin
control assembly to the inside of the bin top
panel. See Fig. 5.
6) Remove the snap pin, shaft and actuator.
7) Remove the sliding door.
8) Soak the removed parts in .25 gallons (1 l)
of sanitizing solution for 10 minutes then
wipe them down.
9) Rinse the parts thoroughly.
IMPORTANT
If the solution is left on these parts, they will rust.
10) Replace all parts in their correct positions.
11) Move the ush switch to the "ICE" position, then turn on the power supply. Replace the
top panel and the front panel in their correct positions. Make ice using the solution until
the icemaker stops making ice.
5. Sanitizing Procedure - Final
1) Remove the front panel and the top panel, then turn off the power supply.
2) Move the ush switch to the "FLUSH" position.
3) Turn on the power supply and drain out all water from the water line.
4) Turn off the power supply.
Note: This unit is designed to start operating when the reservoir is lled with water.
5) In the storage bin, remove the thumbscrews attaching spout (B), then remove spout (B)
and spout packing (B).
6) Remove the thumbscrews attaching spout (A) to the evaporator assembly and lift off
spout (A) and spout packing (A).
7) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are lled and the solution starts to overow into the drain pan.