GTO 4000XLS Instruction Manual © 01.10.12 25
Generation 3 Visual Feedback
SYMPTOM DIAGNOSIS CHECK:
Status (clear)1 blink Cycle Terminal
Shorted
•Disconnectthepushbutton,keypad,intercomkeypad,or
any other accessory wired to this terminal.
•Trytheremote.Iftheremoteworks,thentheproblemis
the accessory.
Status (clear) 2
blinks
Safety Terminal
Shorted
•Disconnecttheloopdetector,photobeam,oranyother
accessory wired to this terminal.
•Trytheremote.Iftheremoteworks,theproblemisthe
accessory.
Status (clear) 3
blinks
Exit Terminal
Shorted
•Disconnectexitwand,loopdetector,photobeam,orany
other accessory wired to this terminal.
•Tryremote.Iftheremoteworks,theproblemisthe
accessory.
Status (clear) 4
blinks
Shadow Terminal
Shorted
•Disconnecttheloopdetector,photobeam,oranyother
accessory wired to this terminal.
•Tryremote.Iftheremoteworks,theproblemisthe
accessory.
Status (clear) 5
blinks
Close Edge
Terminal Shorted
•Disconnecttheedgesensor,photobeam,oranyother
accessory wired to this terminal.
•Trytheremote.Iftheremoteworks,theproblemisthe
accessory.
Status (clear) 6
blinks
Open Edge
Terminal Shorted
•Disconnectedgesensor,photobeam,oranyother
accessory wired to this terminal.
•Trytheremote.Iftheremoteworks,theproblemisthe
accessory.
RF (yellow) Flickers Receiving 318 MHz
RF
•Normaloperationwhenremoteorwirelesskeypadisused.
RF (yellow)OFF No 318 MHz RF
Received
•BatteryinRemote
•ProgramRemote
•AntennaReceiverConnections
•AntennaReceiver
Power (green)
ON
AC or Solar Power
Present
•NormalOperation
VOLTAGE READINGS
18 Vac Transformer 18.0 to 22.0 Vac
10 W Solar panel (single) 18.0 to 22.0 Vdc
In FULL SUN — measure voltage with the Solar Panel Disconnected.
12 V, 7 amp hour Battery 12.5 to 13.5 Vdc
or Two 12V, 7 amp hour Batteries if using solar power
Measure voltage at battery terminals with battery disconnected
Charging circuit 12.0 to 14.8 Vdc