22 GTO 4000XLS Instruction Manual © 01.10.12
Set Control Board for Push-To-Open
Make sure the control box power switch is OFF. Use a small
screwdriver to move the Number 3 DIP switch from the
factory setting (OFF / Pull-To-Open) to ON for Push-To-Open.
Turn power switch ON. The control board is now congured
to push the gate open.
Setting the Open Position Limit (Push-To-Open Installations)
ON
OFF
DIP#3
ON: Push-to-open operation.
OFF: Pull-to-open operation (factory setting).
1
ON
2 3 4
1 2 3 4
ON
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
2ND OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN MAX
AUTO CLOSE TIME STALL FORCE
1 2 3 4
ON DIP
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
Step 1
Power switch is on, gate is
in the CLOSED position,
operator arm
fully retracted.
Step 2
Press the transmitter to
activate operator arm. The
gate will begin to OPEN.
Step 3
When the gate reaches
the desired OPEN
position, press the
transmitter to
stop the gate.
Learn Master
Limit Button
1 2 3 4
ON DIP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
2ND LIMIT
S3
S4
S2
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN MAX
AUTO CLOSE TIME STALL FORCE
Step 4
With the master
gate at the correct
position, program the
open limit setting by
pressing and holding
LEARN MAST LIMIT.
Gate in Closed
Postion
Gate
Opening
Gate
Opened
Control
Box
Control
Box
Control
Box
Step 5
Press the transmitter
again to allow the gate
to return to the fully
CLOSED position.
Gate is now
programmed
The gate open position is now programmed.
If you make a mistake and set the limit at the
wrong position: press your transmitter to return
the gate to the fully closed position, then press
and hold the LEARN MAST LIMIT button for 5
seconds. This will clear the memory for the open
limit position. Repeat Steps 1-5.
Gate in Closed
Postion
Gate open position
is now programmed
Control
Box
ON/OFF Switch
ON/OFF