GTO 10 Safety Gate User Manual


 
GTO 4000XLS Instruction Manual © 01.10.12 13
IMPORTANT:
• Thetransformerisdesignedandintendedforindooruse.Ifthetransformercanonlybe
plugged into an outside electrical outlet, a weatherproof cover/housing (available at local
electrical supply stores) must be used.
• TheonlywireacceptableforusewithGTOproductsis16gaugestranded,lowvoltage,direct
burial wire
[RB509]. This gauge enables the transformer to provide an adequate charge
through the control board to the battery at distances up to 1000 ft.
• DONOTusetelephonewireorsolidwire.
• NEVERSPLICEWIRES.Splicingpermitscorrosionandseriouslydegradesthewire’sabilityto
carry an adequate current.
• NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME! Doing so will
damage the control board.
• Ifyourgateismorethan1000ft.fromanACpowersource,youwillneedtouseatleast10
watts solar charging power
[FM122/FM123] to charge the battery. Refer to the Solar Panels
and Gate Activity Chart on page 2.
Step 1
Make sure the control box power switch is OFF.
Step 2
Select the electrical outlet outlet into which you will plug the transformer. Measure the distance from this
outlet to the control box following the path where the wire will be laid (allow for an additional 6” to be
pulled into the control box).
Step 3
Lay the low voltage wire in a trench following a path from
the selected electrical outlet to the control box. Wires coming
up from the ground should be run through PVC conduit to
protect them from lawn mower blades, weed eaters, and
grazing animals. Bury the wire in the trench.
Step 4
Feed the low voltage wires upward through the strain relief
opening on the lower left of the control box. Pull 6” to 8” of
wire into the control box.
Connect the Power Input
ON/OFF Switch
ON/OFF
Power Cable from
Master Arm
Low Voltage Wire
from Transformer
or Solar Panel
PVC Pipe
GRNCOMCOM
CYCLE
CLOSE
SAFETY
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
EXIT
OPEN
BLK
RECEIVER
RED
25
FUSE
BATT +
BATT -
1 2 3 4
ON DIP
ORGBLUEWHTGRN BRN RED
MASTER INPUTS
BLK
SOLAR
or
18 VAC
ORGBLUEWHTGRN BRN RED
SLAVE INPUTS
BLK
LOCK
GTO AUX