GTO 10 Safety Gate User Manual


 
24 GTO 4000XLS Instruction Manual © 01.10.12
Troubleshooting Guide
If your gate operator does not function properly after it is installed, use this guide before calling the GTO
Service Department.
Generation 3 Audible Feedback
SYMPTOM DIAGNOSIS CHECK:
1 short beep upon
power up
Circuit Board
Powered Up &
Ready
•NormalOperation
1 short beep upon
activation
Blown Fuse
Low or Bad Battery
Loose Battery
Connection
•Fuse
•BatteryUnderLoad
•BatteryHarnessConnections
Continuous
Uninterrupted
Alarm
Circuit Board
Senses an
Obstruction
•PathofGate
•GateforLevelandPlumb
•StallForceAdjustment
•DisconnectSafetyDevices
•RevCounter
1 beep with 10
seconds o
Low Battery
Condition
•Fuses
•BatteryHarnessConnections
•BatteryUnderLoad
1 beep then 2
beeps
Master Motor
Terminals Shorted
•ConnectionstoMasterInputs
•MasterArmPowerCable
•Motor
•CircuitBoard
1 beep with 2
seconds o
Master Arm Limit
Switch Error
•ConnectionstoMasterInputs
•MasterArmPowerCable
3 beeps with 2
seconds o
Master Arm Rev
Counter Error
•ConnectionstoMasterInputs
•MasterArmPowerCable
•RevCounter