Graco 313539F Dollhouse User Manual


 
Flushing
38 313539F
Flushing
Flush out old fluid with new fluid, or flush out old
fluid with a compatible solvent before introducing
new fluid.
Use the lowest possible pressure when flushing.
All fluid components are compatible with common
solvents. Use only moisture-free solvents.
To flush feed hoses, pumps, and heaters separately
from heated hoses, set PRESSURE
RELIEF/SPRAY valves (SA, SB) to PRESSURE
RELIEF/CIRCULATION . Flush through bleed
lines (N).
To flush entire system, circulate through gun fluid
manifold (with manifold removed from gun).
To prevent moisture from reacting with isocyanate,
always leave the system dry or filled with a mois-
ture-free plasticizer or oil. Do not use water. See
page 6.
Flush equipment only in a well-ventilated area. Do not
spray flammable fluids. Do not turn on heaters while
flushing with flammable solvents.
SA
SB
ti9880a
N