j. Manual current control mode only:
If FTS is disconnected or display shows diag-
nostic code E04, turn main power switch OFF
then ON to clear diagnostic
code and enter manual current control mode.
display will show current to hose. Current
is not limited by target temperature.
To prevent overheating, install hose thermome-
ter close to gun end, within operator view. Insert
thermometer through foam cover of A compo-
nent hose so stem is next to inner tube. Ther-
mometer reading will be about 20°F less than
actual fluid temperature.
If thermometer reading exceeds 160°F (71°C),
reduce current with key.
4. Set pressure
a. Press to display the pressure reading.
b. Press motor . Motor and pumps start.
Display shows system pressure.
NOTE:
Motor must rotate counterclockwise when viewed from
shaft end. See Connect electrical cord, page 18.
c. Adjust hydraulic pressure control until display
shows desired fluid pressure.
NOTE:
If display pressure is greater than desired pressure,
reduce the hydraulic pressure and trigger gun to reduce
pressure.
When in manual current control mode, monitor hose
temperature with thermometer. Install per instructions
below. Thermometer reading must not exceed 160°F
(71°C). Never leave machine unattended when in
manual current control mode.
NOTICE
Never adjust hydraulic pressure while spraying. This
will result in over pressure alarm E23.