Graco 313539F Dollhouse User Manual


 
Startup
24 313539F
2. Load fluid with feed pumps
NOTE:
The Reactor is tested with oil at the factory. Flush out
the oil with a compatible solvent before spraying. See
page 38.
a. Check that all Setup steps are complete.
b. Turn on component B agitator, if used.
c. Turn both PRESSURE RELIEF/SPRAY valves
(SA, SB) to SPRAY .
d. Start feed pumps.
e. Open fluid inlet valves (FV). Check for leaks.
f. Use feed pumps to load system. Hold gun fluid
manifold over two grounded waste containers.
Open fluid valves A and B until clean, air-free
fluid comes from valves. Close valves.
Do not mix components A and B during startup.
Always provide two grounded waste containers to
keep component A and component B fluids separate.
ti9877a
SA
SB
FV
ti10972a
ti2484a