Graco 24K960 Stroller User Manual


 
Cleanup
3A2090A Operation 31
Cleanup
1. Perform Pressure Relief Procedure, page 8.
2. Remove guard and SwitchTip.
3. Unscrew cap, remove filter. Assemble without filter.
4. Clean filter, guard and SwitchTip in flushing fluid.
5. Place siphon tube set in grounded metal pail par-
tially filled with flushing fluid. Attach ground wire to
true earth ground. Perform Startup steps 1 - 6 (see
page 9) to flush out paint in sprayer. Use water to
flush water-base paint and mineral spirits solvent
(also called white spirit) to flush oil-base paint.
6. Hold gun against paint bucket and pull trigger until
water or solvent appears.
7. Move gun to solvent or water bucket. Hold gun
against bucket and pull trigger until the system is
thoroughly flushed.
8. Fill pump with Pump Armor and reassemble filter,
guard and SwitchTip.
9. Each time you spray and store, fill throat packing nut
with TSL to decrease packing wear.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
TI3371A
ti6269a
FLUSH
TI3375A
ti3322b