Chamberlain SL 1000-X3 Safety Gate User Manual


 
Rev J Doc 01-20098 Page 18 of 44
K. BASIC GATE OPERATOR PROGRAMMING
Even if you plan to program the gate operator by telephone, you may want to enter some
immediate
instructions during installation. The following list of instructions will help you set
basic
controls so the gate will operate properly until you have time for full programming, either
directly
or by telephone. For complete programming instructions, refer to the SL 1000, SW
2000, BG 3000 Programming Manual.
To access programming mode: enter ✱ ✱ 000000 (3 asterisks, 6 zeroes)
To
program a command: a) enter step number b) enter required data c) enter # (pound sign)
To
exit programming mode: enter 00# (2 zeroes, 1 pound sign)
Step
Purpose
# of
Digit
s
Default Acceptable Input
01 Gate Type
(See
Notes Below)
1 1 0 = Slide, 1 = Swing, 2 =
Barrier,
3 = Linear
02 Operator Type 1 0 0 = Single, 1 = Master, 2 =
Slav
e
03 Pair Type 1 0 0=Bipart, 1=Latch, 2=Not
Used,
3=Tandem
04 Not Used - - -
05 Not Used - - -
06 Anti-Tailgate Enable (ATG) 1 0 0 = Disabled, 1 = Enabled
07 Latch Delay Time 3 6 0 – 250 Seconds (.4 sec.
Increments)
08 Reclose Time (RT) Up to 3 30 0 – 250 Seconds (0 =
Dis
abled)
09 Not Used - - -
10 Not Used - - -
11
Obstruction Sense Backup
Closin
g
Up
to 3 12 2 – 499 Inches
12
Obstruction Sense Backup
Opening
Up
to 3 12 2 – 499 Inches
13 Interrupt Bar Backup If Closing Up to 3 12 2 – 499 Inches
14 Interrupt Bar Backup If Opening Up to 3 12 2 – 499 Inches
15 Return to Factory Set Defaults 6 N/A 101010 (partial), 191919 (full)
NOTES:
1. If Gate Type is set to SLIDE, gate brakes whenever it stops.
2. If Gate Type is set to SWING, gate brakes only when it reaches the open or close limit.
1. If Gate Type is set to BARRIER or LINEAR, the gate never brakes.