ELECTRICAL SYSTEM 16-65
Meter, Gauge, Indic ator Unit
Meter Unit Removal
Remove:
Wind Sealed (see Frame chapter)
Slide the dust cover [A] and remove the wiring connector
[B].
Remove the meter unit by taking off the mounting screws
[C] with the washers.
CAUTION
Place the m eter or gauge so that the face is up. If a
meter or gauge is left upside down or sideways for
any length of time, it will malfunction.
Met
er, Gauge Disassembly
Remove:
Meter Unit (see Meter Unit Removal)
Scr
ews [A]
Lower Meter Cover [B]
Separate the meter assembly [A] and upper meter cover
[B].