DIAGNOSTICS (LEDS AND CODES)
There are three diagnostic LEDs. Two red LEDs (OL, CL) are
indicators for the open and close limits. The LEDs are illuminated
when the limit switch contacts are closed.
The third amber LED (DIA) is used to blink out diagnostic codes.
The number is the count of the number of times the LED is on in
an 8 second period. The LED is on for approximately 1/2 second
and repeats every second until the number is reached. There will
be a pause following each pulse cycle (1-6 pulses) to differentiate
between the different diagnostic codes.
Force Control
Max
Min
LED Code Diagnostic Meaning Cleared By
Flashed
OFF Normal operation N/A
1 Single entrapment sensed Control Input
2 Double entrapment Hard Input*
3 Failed or no hall effect sensor Removal of problem
4 Exceed maximum motor run time Hard Input*
5 Limit fault Control Input
6 Loss of communications between master and second during run mode Removal of problem
On No Flash Motor not learned Completion of Motor Learn Routine
*Hard inputs include open override, close override and stop inputs.
TROUBLESHOOTING
LED LED NAME DESCRIPTION
RELAY DRIVE TROUBLESHOOTING LEDS
There are 5 troubleshooting LEDs on relay drives K1 through K5. These
LEDs will be illuminated when the microcontroller relay drive is activated.
D6 Contactor A On when Contactor A is activated
D5 Contactor B On when Contactor B is activated
D4 SAM On when SAM relay is activated
D3 Lock On when Mag Lock relay is activated
D2 Alarm On when Alarm Relay is activated
TROUBLESHOOTING LEDS
There are 9 troubleshooting LEDs.
LED LED NAME DESCRIPTION
D11 Radio On when Radio switch is activated
D13 Shadow On when Shadow Loop is activated
D15 Hard Close On when Close switch is activated
D17 Stop On when Stop switch is not activated
D19 Soft Open On when Open switch is activated
D21 Hard Open On when Open switch is activated
D24 Interrupt Loop On when Interrupt/Safety Loop activated
D29 Obstruction Open On when Edge is activated or when Photo Eye
Beam is broken
D31 Obstruction Close On when Edge is activated or when Photo Eye
Beam is broken