Adams CFW 60 Building Set User Manual


 
When parts counting- the weight, unit weight and count will be printed:
GS 12.340kg GS for Gross weight, NT for net weight and a unit of weight
UW 123.4g The average piece weight computed by the scale
PCS 100pcs The number of parts counted
<lf> Includes 2 line feeds
<lf>
When recalling the Total weight stored in the accumulation memory the output format
is:
*************** A line of stars is shown
TOTAL
No. 5
Wgt 21.455 kg .
***************
9.1 INPUT COMMANDS FORMAT
The scale can be controlled with the following commands. The commands must
be sent in upper case letters, i.e. “T” not “t”. Press the Enter key of the PC after
each command.
T<cr><lf>
Tares the scale to display the net weight. This is the same as pressing the [Tare] key.
Z<cr><If>
Sets the zero point for all subsequent weighing. The display shows zero.
T12.5<cr><if>
Same as entering a preset tare value of 12.5 from the keypad.
P<cr><lf>
Prints the results to a PC or printer using the optional RS-232 interface. It also adds the
value to the accumulation memory if the accumulation function is not set to automatic.
@Adam Equipment Company 2006
21