6.5 CHECK-WEIGHING
Check-weighing is a procedure to cause an alarm to sound when the weight on
the scale meets or exceeds values stored in memory. The memory holds
values for a high and a low limit. Either or both can be used.
See PARAMETERS Section for the procedure. To set the limits, "F0 H-L" is used.
After limits have been set the Check-weighing function is enabled.
When a weight is placed on the scale the arrows will show if the weight is above
or below the limits and the beeper will sound as described below.
BOTH LIMITS SET The display will show OK and the beeper will sound when the
weight is between the limits.
LOW LIMIT SET HIGH LIMIT is set to zero
The display will show OK and the beeper will sound when the
weight is less than the Low Limit. Above the Low Limit the
display will show HIGH and the beeper will be off.
HIGH LIMIT SET LOW LIMIT is set to zero
The display will show LOW and the beeper will be off when the
weight is less than the High Limit. Above the High Limit the
display will show OK and the beeper will be on.
BOTH LIMITS SET.
LOW IS SET GREATER
THAN HIGH
The beeper will never sound and the display will show LOW if
the weight is less that the LOW limit, and HIGH if the weight is
greater than the Low Limit.
NOTE: Weight must be more than 20 scale divisions for checkweighing to
operate.