Adams CFW 60 Building Set User Manual


 
Checkweighing facility can be set up during Weighing or Parts Counting by entering
values as Low or/and High Limits keyed in by the user. The limits are displayed in
kg or pcs respectively.
Checkweighing during Weighing
Checkweighing during Parts Counting
To disable the Check-Weighing function enter zero into both limits by pressing
the [Func/C] key when the current limits are shown then pressing [Zero/Enter]
to store the zero values.
6.5 ACCUMULATED TOTAL
The scale can be set to accumulate manually by pressing the
[Print/M+] key. See the PARAMETER Section for details of setting
the Parameter "F5 PRT". The accumulation function is only available
when weighing. It is disabled during parts counting.
The weight displayed will be stored in memory when the [Print/M+]
key is pressed and the weight is stable.
The display will show "ACC 1" and then the total in memory for 2
seconds before returning to weighing. If the optional RS-232
interface is installed the weight can be output to a printer or PC.
@Adam Equipment Company 2006