ISS 506 Integration Seamless Switcher • Modications
7-2
Modifications
The ISS 506 can be modified to install or remove optional boards that change the
input and/or output formats that the switcher can process. The following optional
I/O boards are available:
• SDI/HD-SDIinput
• Scanconverter(lowresolution)output
• HD-SDIoutput
• DVIoutput
Modify the ISS by performing the procedures in the following sections, as
applicable:
Opening the Switcher
Installing an Optional SDI/HD-SDI Input Board
Installing an Optional Output Board
Closing the switcher
Opening the Switcher
N
Extron recommends that you send the unit to Extron for service and updates.
To replace or install an optional input or output board, you will to open the ISS’s
case. Open the switcher as follows:
1
. Disconnect the AC power cord from the ISS to remove power from the unit.
W
To prevent electric shock, always unplug the ISS from the AC power
source before opening the enclosure.
2
. If the ISS is installed in a rack, disconnect all signal and control cables and
remove the ISS from the rack.
3
. Remove and retain the 14 screws, 8 on the top and 3 on each side of the ISS
cover (figure 7-1).
ISS 506
Integration Seamle
ss Switc
her
VOLUME
ADJUST
ADJUST
TRANSITION
PICTURE
ADJUSTMENTS
CONFIG
PROGRAM
PREVIEW
EFFECTS
FREEZE
1
2
3
4
5
1
2
3
4
FREEZE
5
LOGO 2
/BLACK
LOGO 1
/BLACK
6
6
LOGO 2
/BLACK
LOGO 1
/BLACK
TAK
E
CUT
TITLE
DISSOLV
E
PIP
WIPE
ZOOM
COLOR
/TINT
CENTER
DETAIL
BRIGHT
/CONT
SIZE
MENU
NEXT
Lift cover
straight up.
Remove 14
screws from
top and sides.
Figure 7-1 — Removing the ISS cover