SIS
Programming and Control, cont’d
ISS 506 Integration Seamless Switcher • SIS
Programming and Control
4-32
Command ASCII (Telnet)
(host to switcher)
URL Encoded (Web)
(host to switcher)
Response
(switcher to host)
Additional description
Scan converter flicker filter
N
The command (d) is case sensitive.
Set flicker filter level
7*
X4!
d 7*
X4!
d 7Dvz
X4!]
Specify the flicker filter level.
Increment flicker filter level 7+d 7+d
7Dvz
X4!]
Increase flicker filter level by one step.
Decrement flicker filter level 7-d 7-d
7Dvz
X4!]
Decrease flicker filter level by one step.
View flicker filter level 7d 7d
X4!]
Show the flicker filter level.
Scan converter encoder filter
Set encoder filter level
24*
X4@
# 24*
X4@
# Enc
X4@]
Specify the encoder filter level.
View encoder filter level 24# 24#
X4@]
Show the encoder filter level.
Miscellaneous Commands
Front panel security lockout (executive mode)
Enable a front panel lock mode
X4%
X
X4%
X Exe
X4%]
Unlock front panel 0X 0X
Exe0
]
View front panel lock X X
X4%]
Command/response table for SIS commands (continued)
N
X4!
= Scan converter horzontal filter / flicker filter value 0 – 3
X4@
= Scan converter encoder filter 0 – 3
X4%