GE FVR-C9S-2UX Drive Series Model Vehicle User Manual


 
22
FVR-C9S-2UX
12. Keypad Panel
Part Names and Functions
Digital monitor:
In program mode, the key-
pad displays the various
function codes and data
values. During operation, it
displays the output fre-
quency, current, voltage, etc.
If a fault occurs, the causes
of the problem will be dis-
played as a code.
PROGRAM key (RESET
key): Normal mode or pro-
gram setting mode select
key. If a fault occurs, this key
is used to reset the fault.
FUNCTION key (DATA key):
During normal mode, this key
can be used to change the display unit
(frequency display and output current dis-
play) while operation is either stopped or
running. During the program setting mode,
this key can be used to read and write the
function codes and data.
RUN key: This key is
used for starting
operation. The LED
(green) lights up
during operation. This
key does not function
when terminal opera-
tion control F02_ _ 1
is selected.
STOP key: This key is
used for stopping
operation. This key
does not function
when terminal opera-
tion control F02 _ _1
is selected.
UP/DOWN keys: These keys increase or
decrease the frequency. When unit is in
program setting mode, they change the
function code or data values.
Controlling Method for Keypad Panel
1) Monitor change
During the normal mode, frequency display and
output current display can be changed by
pressing the FUNC/DATA key.
2) Run/Stop
When F02 is _ _ 0): Press RUN) to run drive; press STOP to stop drive.
3) Frequency change
When F01 is _ _ 0: Press UP to increase frequency; press DOWN to decrease frequency.
Note) If FUNC/DATA is pressed while pressing UP or DOWN, frequency changing speed
increases.
PRG
RESET
FUNC
DATA
RUN
STOP
FVR-C9S
8. 8. 8.
6 0. 0
1. 2 A
FUNC
DATA
FUNC
DATA