GE FVR-C9S-2UX Drive Series Model Vehicle User Manual


 
20
FVR-C9S-2UX
RUN
STOP
Time
Frequency
Forward
Reverse
FWD-CM
REV-CM
ON
ON
Frequency
11. Operation
Pre-Operation Inspection
Check for wiring errors.
Check that all loose wire stands, metal
chips and unnecessary screws, etc. have
been removed.
Check that no screws, terminals, etc. are
loose.
Check that the wire ends of crimp terminal
are not in contact with other terminals.
Test Run Check Points
Smooth rotation and correct rotation
direction.
No abnormal vibrations and noise from the
motor.
Smooth acceleration and deceleration.
Frequency Setting Method
Frequency setting by potentiometer con-
trol (factory preset at the time of shipment;
F01:1). As wired at the factory, frequency
setting can be performed by turning the
potentiometer control knob on the keypad
panel. Turn the potentiometer control knob
clockwise to increase frequency.
• Frequency setting by digital signal (F01 :
0). With the function F01 set to 0, fre-
quency can be increased or decreased by
the
UP/DOWN) keys on the keypad panel.
UP: Frequency up
DOWN: Frequency down
RUN/STOP Method
RUN/STOP by keypad panel operation
(Factory preset at the time of shipment
F02:0).
The drive is shipped with a factory in-
stalled jumper, between FWD-CM. Only
forward operation is possible. To enable
reverse operation remove the jumper from
FWD/CM and install the jumper between
REV-CM.
RUN/STOP by terminal operation (F02 : 1)
Note) Open FWD and REV terminals when
changing F02 data. Data cannot be changed
if not open.