DKS Enterprises 6100 Safety Gate User Manual


 
6050-065-L-11-08
20
Reverse loop lead in
wires are twisted
approx. 6 twists per
foot and are wired in
series.
Shadow loop lead
in wires are twisted
approx. 6 twists
per foot.
Automatic exit loop
lead in wires are
twisted approx. 6
twists per foot.
Reverse
Reverse
Shadow
Automatic Exit
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
NC
NO
POWER
1
ON
2 3 4 56 7 81
ON
2 3 45 6 7 8
2.7 Loop Detector Wiring
If other detectors are used, use a separate power
supply to power these detectors.
Loop layout shown is for a typical swing gate
application with two-way traffic, or one-way exit
only traffic.
Refer to the Loop Information Manual (available
from www.dkaccess.com) for more information
on loops and loop detectors.
Loops and loop detectors MUST be installed with this gate operator
to help prevent the gate from accidentally closing on vehicular traffic.
Loop detector wiring is shown for DoorKing plug-in loop
detectors only. If other loop detectors are used,
refer to the installation instructions supplied with
those detectors for wiring instructions.
Com
9410
9409
N.O.
Shadow Loop Output
1
ON
2 3
3
4 5 6 7 8
SW 2
SW 2
SW 1
SW 2, switch
1 and 2 must
be OFF.
switch 5,
must be OFF.
Relay must
be set to N.O.
NO
NC
4502