DKS Enterprises 6100 Safety Gate User Manual


 
6050-065-L-11-08
17
2.3 Main Terminal Description
lf SW 1, switch 3 is ON,
this input is identical to
Single Button Activation.
lf SW 1, switch 3 is OFF,
this terminal becomes the
logic output of the loop
detector that is plugged into
the open (Exit) loop port.
1
ON
2 3 4 5 6 7 8
SW 1
When gate is closed, input will open gate.
When gate is open and auto close
timer SW 1, switch 4 is turned on,
input will re-set and hold timer.
When gate is open and auto close
timer SW 1, switch 4 is turned off,
input will close gate.
When gate is closing, input will
reverse gate.
1
ON
2 3 4 5 6 7 8
SW 1
When gate is closed, this input has no
affect on the gate operator.
When gate is open and auto close
timer SW 1, switch 4 is turned ON,
input will re-set and hold timer.
When gate is open and auto close
timer SW 1, switch 4 is turned OFF,
input will prevent gate from closing.
When gate is closing, input will
reverse gate if SW 1, switch 5 is OFF.
When gate is closing, input has no
affect on the gate operator if SW 1,
switch 5 is ON (set for shadow input).
1
ON
2 3 4 5 6 7 8 1
ON
2 3 4 5 6 7 8
SW 1
SW 1
Operation of relay is dependent on
setting of SW 1, switches 1 and 2.
Relay contacts can be set for
Normally Open (NO) or Normally
Closed (NC) operation. Contact
rating is 1 amp maximum at
24-volts DC.
1
ON
2 3 4 5 6 7 8
NC
NO
SW 1
24-volt DC magnetic lock power
is provided constantly except when
the gate is opening or open.
18
16
15
12
11
LOW VOLTAGE COMMON
LOW VOLTAGE COMMON
MAGNETIC LOCK OUTPUT
DRY RELAY CONTACT
DRY RELAY CONTACT
CLOSE INPUT
(Use DoorKing 3-Button station ONLY)
OPEN INPUT
(Use DoorKing 3-Button station ONLY)
REVERSE (SAFETY) INPUT/
SHADOW INPUT
SINGLE BUTTON ACTIVATION INPUT 2/
OPEN LOOP LOGIC OUTPUT
SINGLE BUTTON ACTIVATION INPUT 1
24 VAC Radio Receiver Power Only
(250 ma. maximum)
12 VAC Magnetic Counter Power Only
(150 ma. maximum)
PULSE 1
Input from Primary Operator
PULSE 2
Input from Secondary Operator
NOT USED
115 VAC MOTOR (CLOSE)
115 VAC MOTOR (OPEN)
115 VAC POWER INPUT
115 VAC POWER NEUTRAL
115 VAC POWER NEUTRAL
Output to Secondary Operator
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
NC
NO
1234567812345678
DANGER
HIGH VOLTAGE!