NOTE: The scale must be originally built for the capacity selected. The 6 kg unit uses
10kg load cells, the 15 kilogram unit uses 20 kilogram load cells and the 30 kilogram unit
uses 35 kilogram load cells.
6.2.4 F4 WEIGHT DECIMAL POINT POSITION
To enter this parameter, press the [Tare] key when “F4” is shown.
The display will show the current decimal point location in the Weight window.
Press the [PLU4] key to change the value and press [Tare] to accept the value.
NOTE: Only certain positions are allowed for the AZplus scales.
6.2.5 F5 -UNIT PRICE/TOTAL PRICE DECIMAL POINT LOCATION
To enter this parameter, press the [Tare] key when “F5” is shown.
The display will show the current decimal point location in the Unit Price and the Total
Price windows.
Press the [PLU4] key to change the value.
Press [Tare] to accept the displayed value.
NOTE: The units must match the currency used in the country. Normally 0.00 is
shown.