Adam Equipment AZplus 30 Building Set User Manual


 
© Adam Equipment Company 2007
18
6.2.1 F1 -CALIBRATION
To enter the calibration parameter, press the [Tare] key when “F1” is displayed.
The display will instruct you to remove any weight from the scale, “UnloAd
The display will tell you to add weight to the scale: “LoAd” “ 15” “kilo
Add the weight shown, wait for stability then press the [Tare] key.
The display will show “
SPAn” “PASS” if the calibration is OK. Or it will show “SPAn” “FAIL” if
calibration could not be completed correctly.
The scale will return to the parameter menu.
6.2.2 F2 -RESOLUTION
To enter this parameter, press the [Tare] key when “F2” is shown.
The display will show the current resolution, either 3000 or 6000 or Dual Range.
Press the [PLU4] key to change the value.
Press [Tare] to accept the displayed value.
NOTE: Only 3000 is allowed for the AZplus scales.
6.2.3 F3 -CAPACITY
To enter this parameter, press the [Tare] key when “F3” is shown.
The display will show the current capacity in 6, 15 or 30 kilograms.
Press the [PLU4] key to change the value.
Press [Tare] to accept the displayed value.