A SERVICE OF

logo

Syntax
{
Start of Header
I
,
Configuration Header
1 - 8 optional records
A, parameter 1...parameter 5
p
System Setup
B, parameter 1...parameter 5
p
Supply Setup
C, parameter 1...parameter 5
p
Print Control
D, parameter 1...parameter 3
p
Monetary Formatting
E, parameter 1...parameter 9
p
Control Characters
F, parameter 1...parameter 5
p
Communication Settings
}
End of Header
Syntax for single packet
{
Start of Header
I
,
Configuration Packet
Identifier
A, parameter 1...parameter 5
System Setup
}
End of Header
You can also add a configuration to non-volatile RAM or specify
units for supply, print, margin, and cut positions. If you use the
optional parameters with the
I
packet, any online configuration
packets following the split vertical bar ( p ) must specify distances
using the selected units. However, the diagnostic labels display
the units in dots, even if you entered them in English or Metrics
units.
Syntax
{I,
p
}
Example
{
I
,
p
C,0,25,0,0,0
p
}
Adds a configuration to non-volatile RAM and specifies English
units. It also uses the default contrast, moves print 0.25 inches
closer to the bottom of the supply and does not change the
margin adjustment, prints at the default print speed, and uses the
default printhead width.
Example
{
I
,0,U,N
p
}
Uploads the printer configuration from nonvolatile RAM and
returns the following to the host.
A,0,0,0,0,1
p
B,2,0,0,0,0
p
2-6
Configuring the Printer